| Type |
EPO-01 |
| 2wire supply |
12÷36V DC * |
| Power consumption |
<1 VA |
| Max. measuring range |
0÷300° |
| Range setting |
50÷100% |
| Output signal |
4÷20mA |
| Conversion characteristic |
linear of change the angle of rotation of encoder's axis |
| Overload resistance |
0÷Rmax<1kΩ Rmax=(Uz-12V)/20mA |
| Conversion error |
<0,5 % |
| Hysteresis for FSO** |
<±0,2 % |
| Protection degree |
IP64
|
| The error of influence the ambient temperature for FSO** |
<0,15 %/10°C |
| Resistance of vibrations |
5G |
| Working temperature |
-40÷80°C |
| Mechanical life |
life10*106 or 1*106 deppends of version
(look at ordering method)
|
| Mass |
80g |
| Length of leading wire |
0,5 running metre |
* wires „+” and „-” have connection with PE by transils at voltage 63V
** FSO – max. range